-40%

2400 WATT PMA 48V Permanent Magnet Alternator Generator PC1248DC 4 ENGINE USE

$ 110.85

Availability: 28 in stock
  • Condition: New
  • MPN: Wind Turbine Generator
  • Refund will be given as: Money Back
  • Brand: Windturbineusa.com
  • Item must be returned within: 30 Days
  • Current Type: DC
  • Return shipping will be paid by: Seller
  • Restocking Fee: 20%
  • All returns accepted: Returns Accepted

    Description

    NOT FOR WIND TURBINES
    made for engine and hydro use only.
    Below is a video of our dual-core model
    This Auction is for a #PC1248-DC PMA
    1800 RPM recommended shaft
    speed for 97% efficiency and
    2700 RPM (Max) at 92%
    electrical efficiency.
    2700 RPM MAXIMUM!
    1075 RPM for >24 Volts.  OPEN VOLTAGE
    1821 RPM for >48 Volts.  OPEN VOLTAGE
    2065 RPM for >60 Volts.  OPEN VOLTAGE
    2500 RPM for >127 Volts. OPEN VOLTAGE
    2400 Watts peak power!
    Closed
    voltage is always the voltage of the battery bank. The battery dominates the voltage spectrum so a battery can take on higher voltages easy. Note: You must use a battery regulator when using an unregulated PMA for charging to make sure the battery does note go above its maximum voltage range.  As long as the battery is below its maximum range it can take in-rusher of higher voltage without any problems but it may never exceed its maximum range so you need a battery regulator to ensure safe charging.
    See this link for a regulator: http://www.ebay.com/itm/332752692942
    Voltage will be much higher if not tied down to a
    battery bank within RPM voltage range shown above.
    GET YOUR BATTERIES CHARGED UP REAL FAST ON THOSE
    GLOOMY WINTER DAYS
    WITHOUT ANY SOLAR OR WIND.  Use a simple gas lawn mower engine.
    To keep your batteries alive when using a power inverter during power outages you need a 48 volt battery regulator.
    The is the best /  #G5 battery regulator
    CLICK HERE TO BUY a  #G5 - 48 VOLT BATTERY REGULATOR
    Fantastic Thermodyne QC1212 PMA portable boost power pack 12/24v - YouTube
    Video will open in a new window
    Using the eBay App? Paste link into a browser window:
    [isdntekvideo]
    SEE VIDEO ON HOW TO USE IT.
    CLICK HERE!
    HIGHLY EFFICIENT - USE LESS GAS OR DIESEL AND MAKE TWICE
    THE ELECTRICITY USING A BATTERY AND POWER INVERTER!
    BEATS TYPICAL 110/220-VAC GENERATORS BY 35% MORE EFFICIENCY.
    Also highly recommended for engine, hydro and belt driven applications!
    The wire size in these stators are extra large coils offering HIGH amperage. This wire is not fine enough for wind power applications
    Includes cooling fan and pulley as standard equipment.
    DO NOT REMOVE COOLING FAN! This model can get hot! VERY POWERFUL!!
    Build a super battery charger out of any old lawn mower.
    Specially made for belt drive use on engines or direct drive Hydro systems.
    Lawn mower not Included.
    THE WORLDS HIGHEST
    AMPERAGE
    PMA FOR IT'S SIZE AND CLASS RANGE !
    Brand new, never used PMA!
    Including the pole shoes and stator coil frame!
    We make our own brand new
    ROTOR POLE SHOES
    AND STATOR CORES!!!
    Make sure your rotor is brand NEW and
    has also been re-balanced on a
    dynamic
    rotor balancing machine or your PMA
    will NOT spin smoothly!!!
    Our PMA's
    are
    NOT
    re-built units
    starting with 'Junk Yard' alternator parts.
    Our
    NEW
    rotor poles are balanced to within .002 grams for SMOOOOOTH rotation!
    Includes 60mm pulley and cooling fan FREE!
    Three-phase units require a Three-Phase
    AC to DC
    rectifier I
    n order to charge batteries
    See link to approved
    rectifier for this model
    -
    LINK HERE
    LOW COGGING  / Power-Core PMA's have
    amazing power and GREAT low speed start up! Can be run Clock Wise (CW) or Counter Clock Wise (CCW) but when running CCW the shaft requires a "Carter pin lock" to keep the pulley from coming off the shaft.
    A must have item for off grid emergency power
    for those days when there is no sun or wind!
    2700 RPM MAX!
    By Hornet Power Systems
    Use these powerful permanent magnet alternators
    (PMA's) to make cheap electricity with wind turbines
    Stop wasting up to 50% of your power energizing the
    coil of standard brush type alternators. Get a real PMA!
    Permanent magnet alternators are by no means standard "Automotive" alternators containing brushes and electro-magnetic coils. A PMA does not waste power by having to continuously create an energy intensive magnetic field.
    We sell only
    highly efficient - long lasting
    true permanent magnet alternators with Neodymium Magnets!
    PMA rotor is
    studded
    with 14 powerful  magnetic  power points -  Arranged in a Superbly balanced and perfectly phase biassing configuration. This new design feature offers high power with no appreciable cogging once at running speed.
    All magnets are all slotted into multi-layered steel plates for maximizing and sharing the rear field forces boosting the overall core power.
    When ordinary stator coils are hyper magnetically saturated with the
    Power-Core
    s
    powerful magnetic field, power outputs are almost tripled over older mono core designs!
    LOTS OF LOW END POWER GENERATION ABILITY!!!!
    Perfect for building simple, inexpensive and dependable wind turbines.
    A put-up and forget design! Expect decades of dependable service life.
    All weather rated.
    Rain, ice and weather proof electronics.
    17MM hardened shaft.
    Heavy Duty coils and diodes.
    Light weight aluminum body.
    Bearings rated for 115,000 hours +
    Warrant
    y - 90 days parts and labor.
    Powerful
    Neodymium magnets in rotor.
    Includes FREE pulley and cooling fan !!
    Bi-rotational. Makes power when turned in either direction
    .
    Pulley and fan comes with all models !
    (Smaller pulley sizes will slip on this ultra powerful model)
    PC series PMA's weigh 14 LBS. - Size 8" X 7" X 7"
    WARNING; High voltage PMA's and battery banks can cause lethal electric shock!
    PLEASE NOTE: Our model numbers have nothing to do with voltages, they are just model numbers
    GET FREE HOT WATER WHEN YOU USE WATER COOLED ENGINES
    PMA Testimonials
    I don't know if you remember me about 2 years ago I was asking you questions about your PMA's. They are great, attached is a photo of my engine setup that has over 5000 hours on them. I've just completed a 48 volt system and now am looking to finding out something about your HT48. At what wind speed does it start producing 48 volt power - even 10 watts? I'm thinking of putting two in series, isolating the ground or case in order to get them to produce something at a low wind speed.
    Thanks
    Bill Miller
    WARNING!! Make sure you connect a PMA to the correct battery polarity. Positive PMA to positive battery terminal and negative PMA to negative battery terminal. IF you reverse the connections you will burn out your PMA as the power rushes past the blocking diodes and melts your coils!!!
    HEAT WARNINGS:
    Keeping your PMA's cooled, fused and under reasonable loads is the operators full responsibility. Monitor your PMA for excessive heating in all experimental machinery! Maximum PMA's operating temperature is 212 F. for 100% duty cycle. No warranties on ANY burned out PMA's! They are sold in good working condition and you have to keep them cool and never over loaded regarding amperage draw.
    A PMA RUNNING SLOW WHILE DRAWING A FULL AMP LOAD IS A DEAD PMA!
    Choose the right PMA and keep it cool via the correct RPM V. AMPS coefficient
    These figures must then be matched to the power curves. This total calculation must
    be done
    correctly or you may find yourself burning up a few PMA's as part of your learning curve.
    (Expensive lessons for the inexperienced!)
    This advice is ONLY a guide line and is not a guarantee of cool operation since your amp load can still be too extreme for proper cooling. For a 48 volt battery system start with a 10 amp fuse and work your way up to no more than 25 amps always making sure the PMA stays under 212 F. or under the temperature for boiling water. Don't pull more amperage than the PMA can handle. If you burn one up you own it!!! No warranties on burned up PMA's!!! All sales Final. If you are an amateur and do not understand electrical windings and how much heat they can take please don't buy one of our PMA's. If you are experienced watch for over heating and be careful. These PMA's really pack LOTS of POWER in a small package! Small power to size ratios always means
    High Performance so
    be careful!
    TECH NOTES:
    Taking apart a PMA the right way.
    1. Remove the 4 housing bolts and pull the front housing off OVER the shaft. Never pull the rear housing off first!!!!
    If it is jammed or rusted use some WD-40 on the shaft and alternately tap the mounting wings with a hammer while applying pressure to the shaft with your thumb so that the stator and it's delicate wiring harness is kept in place. NOTE: If the shaft is QCored-up badly you may have to sand the shaft down to it's original 17mm size to get the front housing off.
    2. Now grab the exposed rotor core shaft and pull it out WHILE holding down the stator ring with your index
    finger and thumb. This will take LOTS of strength!!!!! If you fail to hold the stator in place the core and stator
    will be extracted together and the wires will be torn off of the stator and this is unrepairable! This is a tricky maneuver and usually takes some experience and lots of muQCle!!!!!!!
    3. Once the rotor core has been successfully extracted the rectifier connections are exposed and you may now unfasten the three wire nuts to safely remove the stator coil. (To reassemble simply reverse procedure)
    Warranties will be void on any PMA that is opened by a customer.
    Any PMA experimentation and examination is at your own risk.
    CLICK DRAWING TO ENLARGE